Owner`s manual

100
---------------------------------------------------------------
| Port | Baud | Word | Stop |Parity| Xon / Xoff | Line |
| | Rate | Size | Bits | | Xmit | Recv | Interface |
---------------------------------------------------------------
| 1 |115200 | 8 | 1 |None | Off | Off | EIA-232 |
---------------------------------------------------------------
Exit/Save......1 Set Stop Bits..4 Set Line Interface..7
Set Baud Rate..2 Set Parity.....5
Set Word Size..3 Set XON/XOFF...6
Enter Request :
You can now select other options from the menu. For
example, to change the line interface to EIA-422, type
"7" (Set Line Interface) and the V71 will respond with:
1 for EIA-232
2 for EIA-422
3 for 20mA Current Loop
Enter Request :
Type "2" for EIA-422 line interface and the V71 will
respond with the reconfigured status of the port, the
option menu, and the prompt:
---------------------------------------------------------------
| Port | Baud | Word | Stop |Parity| Xon / Xoff | Line |
| | Rate | Size | Bits | | Xmit | Recv | Interface |
---------------------------------------------------------------
| 1 |115200 | 8 | 1 |None | Off | Off | EIA-422 |
---------------------------------------------------------------
Exit/Save......1 Set Stop Bits..4 Set Line Interface..7
Set Baud Rate..2 Set Parity.....5
Set Word Size..3 Set XON/XOFF...6
Enter Request :
If there are no other changes, send "1" (Exit/Save) and
the V71 will return to the main configuration menu (see
Section 11.1).
NOTE: The new serial port configuration changes do not
take effect until after you exit configuration mode for
the V71.