Owner`s manual

146
You must send $BTX<cr> ($BAYTECHX<cr> with M4 and
M8 DAC) to select the module as described in Step 2
where X = 1 to 16, then continue with Step 3.
16.1V50/V73/V74/V75/V76/V86/V87 MAIN
CONFIGURATION MENU
The V50/V73/V74/V75/V76/V86/V87 module responds to
the receiving of $CONFIG<cr> with an identification
block and a menu of the available configuration options,
similar to the following:
Copyright(C) Bay Technical Associates 199X-199X
Model V73/V74/V76 etc. High Speed Serial 4C
Revision F.X.XX
Unit: 1, Module: 2
Status.....................................1
Serial Port Configuration..................2
Port Device Name...........................3
Port I.D...................................4
Designate Host Port location...............5
Message Terminate Character................6
Mode of Operation..........................7
Time Tag Mode..............................8
Connect Port ID Echo.......................9
Port EIA Driver............................A
Exit.......................................X
Enter Request :
NOTE: Menu selection is case sensitive. It is
recommended that your keyboard be in the CAPS LOCK
position. Item "A" (Port EIA Driver) applies to the V86
isolated EIA-485/422 module only.
IMPORTANT: If you change the Message Terminate
Character or Mode of Operation, when you type "X" from
the above menu (Exit), the module will respond with:
Mode Of Operation or Terminate Character has been Changed!
Press Any Key To Reset This Unit...
Typing any key results in the M Series base unit and all