Owner`s manual

148
Port I.D...................................4
Designate Host Port location...............5
Message Terminate Character................6
Mode of Operation..........................7
Time Tag Mode..............................8
Connect Port ID Echo.......................9
Port EIA Driver............................A
Exit.......................................X
Enter Request :
You can make whatever changes are necessary by
responding to the above menu. The Exit function
returns you to Operations Mode.
16.3V50/V73/V74/V75/V76/V86/V87 SET
SERIAL PORT CONFIGURATION
By responding to the Enter Request: message at the
end of the main configuration menu (see Section 16.1)
with "2" (Set Serial Port Configuration), you can change
the serial configuration for each port of the
V50/V73/V74/V75/V76/V86/V87 module (i.e., baud rate,
word size, stop bits, parity, and XON/XOFF
handshaking). The module translates between devices
of different configurations without the need to
reconfigure the devices. The module will respond with:
Enter Serial Port Number (? = Help, ENTER = Exit) :?
Type the port number of the selected module that you
wish to reconfigure followed by <ENTER>. If you wish
to review the status of the selected module, type "?".
For example, if you enter "4", the module responds with
the current status for Port 4 and a list of available
options as follows:
Current Module 2 Serial Port Configuration :
+------+------------------+-------+------+------+------+------+------+
| Port | Device Name | Baud | Word | Stop |Parity| Xon / Xoff |
| | | Rate | Size | Bits | | Xmit | Recv |
+------+------------------+-------+------+------+------+------+------+
| 4 | Device D | 9600 | 8 | 1 | None | Off | Off |