Owner`s manual

150
module will respond with:
Output Flow Control (Xmit) - Xon/Xoff is ( OFF )
Stop/Restart Output Upon Receiving of Xoff/Xon ? (Y/N) :
You should then enter "Y" to enable XON/XOFF on
transmit or "N" to disable XON/XOFF on transmit.
Following our example, enter "N" and the module will
respond with:
Input Flow Control (Recv) - Xon/Xoff is ( Off )
Xoff/Xon sent based on Buffer - Full/Empty condition ? (Y/N) :
You should then enter "Y" to enable XON/XOFF on
receive or "N" to disable XON/XOFF on receive.
Following our example, enter "Y" and the module will
respond with the reconfigured status for Port 4 as
follows:
Current Module 1 Serial Port Configuration :
+------+------------------+-------+------+------+------+------+------+
| Port | Device Name | Baud | Word | Stop |Parity| Xon / Xoff |
| | | Rate | Size | Bits | | Xmit | Recv |
+------+------------------+-------+------+------+------+------+------+
| 4 | Device D | 115.2K| 8 | 1 | None | Off | On |
+------+------------------+-------+------+------+------+------+------+
Exit/Save......1 Set Stop Bits.....4
Set Baud Rate..2 Set Parity........5
Set Word Size..3 Set Xon/Xoff......6
Enter Request:
If there are no other changes for this port, send "1"
(Exit/Save) and the module will respond with:
Save Changes Permanently ? (Y/N) :
If you type "Y", the new configuration for the selected
port is stored permanently in non-volatile memory and
the module will subsequently power up at the new
configuration. If you type "N", the new configuration is
stored in RAM and lost once power is removed from the
unit. After you type the desired response to the save
changes prompt, the module will respond with: