The module will respond with:
Enter New Host Port Number (1 - 4):
Type the desired port number followed by <ENTER>.
NOTE: If a V71 is the designated host module, the host
port number is "1" (default). If the base unit is the
designated host module, the host port number is "1" for
the service port or "2" for the service modem.
All completed messages received while operating in
immediate reporting mode are sent to the designated
host port.
16.7V50/V73/V74/V75/V76/V86/V87
CHANGE MESSAGE TERMINATE
CHARACTER
By responding to the Enter Request: message at the
end of the configuration menu (see Section 16.1) with
"6" (Change Message Terminate Character), you can
program the message terminating character. The
module will respond with:
Current Terminate Character is.............0DH
Enter Terminate Character in Hex
or ENTER for no change ....................:
Enter the desired message terminating character in the
form of a two-digit hexadecimal character from 00 Hex
to 7F Hex. For example, if you enter "0A" (Line Feed),
the module will respond with:
Current Terminate Character is.............0AH
Enter Terminate Character in Hex
or ENTER for no change ....................:
If the displayed terminate character is satisfactory, type