Owner`s manual

12
3. Access configuration mode by sending
$CONFIG<cr>. Following the example on the
previous page, you would send
$BT1<cr>$CONFIG<cr> to configure Module 1.
Use $BAYTECH1<cr>$CONFIG<cr> on M4 and M8
units.
1.3.3 MAIN UNIT CONFIGURATION
You can program the date, time, and unit number on the
main unit. The date and time are used for event
recording and initiation. When you access configuration
mode for the main unit from a host module or the
service port, you will receive the following menu:
Control Board System Menu
Bay Technical Associates
Copyright 199X
Unit Number 001
Set Date.................1
Set Time.................2
Set Unit Number..........3
Exit System Menu.........X
Enter Request:
1.3.4 HOST MODULE CONFIGURATION
You can program the port select code and the serial port
configuration (i.e., baud rate, word size, line interface,
etc.) of the V71 host module. If you access
configuration mode for the host module, you will receive
the following menu:
Copyright (c) Bay Technical Associates, 199X
DAC V71 Rev. X.XX
This Module is 1
1) Status
2) Port Select Code
3) Serial Port Configuration