Owner`s manual

14
1.3.5 V77 ADM-1 CONFIGURATION
You can program the sampling setup, reporting setup,
channel input setup, and enable dynamic configuration
for the V77 ADM-1 analog-to-digital module. If you
access configuration mode for the V77 ADM-1, you will
receive the following menu:
Copyright (c) Bay Technical Associates, 199X
DAC V77 ADM-1 Rev. 1.00
This Module is X
Module Status..................1
Sampling Setup.................2
Reporting Setup................3
Channel Input Setup............4
Dynamic Configuration..........5
Exit...........................X
Enter Selection:
SAMPLING SETUP
By entering a "2" (Sampling Setup), the following menu
will be displayed:
Sampling Method.................1
Sample Start Time...............2
Sample Interval.................3
Sample Rate.....................4
No. of Samples to Average.......5
Exit............................X
Enter Selection:
The three Sampling Methods are Command (upon
request only), Immediate (upon exiting configuration),
and Schedule (where sampling begins at the Sample
Start Time). Sample Interval is the interval between
the start of sampling periods. Continuous sampling is
selected if 00:00:00 is entered. Sample Rate can be
programmed from 1 to 4000 samples per second. The
sample rate for an individual channel is the programmed
rate divided by the number of active channels. Number