Owner`s manual

18
Range and Unipolar/Bipolar are used to choose one of
eight different voltage ranges. These are 0 to +10
volts, -5 to +5 volts, 0 to +5 volts, -2.5 to +2.5 volts, 0
to +2.5, -1.25 to +1.25 volts, or 0 to +1.25 volts,
-0.625 to +0.625 volts. You can select a ninth voltage
range which is -10 to +10 volts by installing JP1. Single
Ended/Differential setting is used to select up to 16
single-ended channels or up to 8 differential channels.
Active Channels enables or disables individual channels
for data acquisition.
DYNAMIC CONFIGURATION
By entering "5" (Dynamic Configuration) from the ADM-1
main menu shown on Page 8, the following menu will be
displayed:
Dynamic Configuration Commands are..Enabled
Enable..............................1
Disable.............................2
Exit................................X
Enter Selection:
You can enable or disable the dynamic configuration
mode from this menu. Dynamic configuration mode
allows non-verbose or "on-the-fly" configuration
commands to be issued to the module which are
described in the manual for each respective module.
1.3.6 V78 CRM-1 CONFIGURATION
You can program the Schedule, Reporting Setup, and
Dynamic Configuration for the V78 CRM-1 control relay
module. If you access configuration mode for the V78
CRM-1, you will receive the following menu:
Copyright (c) Bay Technical Associates, 199X
DAC V78 CRM-1 Rev. 1.XX
This Module is X
Module Status...................1