Owner`s manual

32
The following example shows messages received using
immediate or schedule reporting where the PDI-1 or
PDI-2 is installed in Unit 1 Module 15 with Time Tagging
enabled:
1:15,1 1 11/18/97 09:12:22<cr><lf>
1:15,2 1 11/18/97 09:12:22<cr><lf>
where 1:15,1 represents Unit 1/Module 15/Channel 1,
1:15,2 represents Unit 1/Module 15/Channel 2, 1
indicates that Channel #1 and Channel #2 are closed,
11/18/97 09:12:22 is the time tag which is the same
for both channels in this example, and <cr><lf> is the
Carriage Return and Line Feed terminating characters.
The following examples show the messages received
using command reporting where the PDI-1 or PDI-2 is
installed in Unit 1 Module 15 with time tagging enabled.
If you select the module and issue the RD1<cr>
command (Report Event Duration), the module responds
with a single message showing the Event Duration for
Channel 1 similar to the following:
1:15,1 1320 11/18/97 09:12:22
where 1:15,1 represents Unit 1/Module 15/Channel 1,
1320 indicates the event duration is 1320 milliseconds,
and 11/18/97 09:12:22 is the time tag.
If you issue the RC1<cr> command (Report Event
Counter), the module responds with a message showing
the Event Counter similar to the following:
1:15,1 823 11/18/97 09:12:22
where 1:15,1 represents Unit 1/Module 15/Channel 1,
823 indicates the number of recorded events is 823
times, and 11/18/97 09:12:22 is the time tag.