6.3 BASE UNIT DYNAMIC CONFIGURATION
COMMANDS
You can configure the date and time for the base unit
from a host communications module by sending the "ST"
(Set Time) dynamic configuration command. The host
communications module must first select base unit prior
to sending the "ST" command. This is done by sending
the port select code, "0", and Carriage Return or Line
Feed. The format of the "ST" command is as follows:
ST HH:MM:SS,MM/DD/YY<cr>
HH is the desired hour, the first MM is the desired
minute, SS is the desired second, the second MM is the
desired month, DD is the desired day, YY is the desired
year, and <cr> is Carriage Return.
For example, if using the default port select code ($BT)
and you wish to program the time and date to 11:59:59
on December 31, 1999, you would send the following
from the host device:
$BT0<cr>ST 11:59:59,12/31/99<cr>