Specifications

Page 4 of 10
75.0082.05 20080125
REMOTE
CONTROL
POWER-UP
PROCEDURES
Upon completion of mechanical and electrical installation, apply 12 to 24 V AC / DC +/- 10% to the DK-12, with the
door in the closed position.
NOTE
: Refer to Programming/Set-up Section.
All adjustments to the DK-12 will be made by BEA’s infrared (IR) remote control. The IR remote control enables the
installer to set-up and adjust the detector. The remote uses a modified code, which makes it incompatible with the
majority of consumer electronics. Because the end cap blocks the IR receiver after installation, no access code is
required.
To adjust the DK-12, stand to the left of the detector, aim the remote towards the left side of the detector (with the
end cap removed) at a distance less than 6 feet from the DK-12. Each adjustment requires pushing two buttons on
the remote; a ‘function’ button and then a number. Certain buttons are not used by the DK-12 and if they are
pushed, will be ignored.
These 5 Keys Not Used
Lock (not used on DK-12)
Minus Key
Relay Output
Auto-Learn Time
(Set up) Closed or Open
Reset Factory Values
Frequency
Number Keys
Not Used
Plus Key
Check Values
Unlock (not used on DK-12)
Relay Hold Time
Sensitivity
Pattern Width
Not Used