User`s guide

75.5134.10 EN 20110519 Page 6 of 13
BEA’S
UNIVERSAL
REMOTE
CONTROL
The Bodyguard is fully compatible with BEA’s Remote Control as shown below. Use of the remote control should be
conducted within 10’ – 15’ of the sensor, and the remote should be pointed directly at the sensor when used. Refer to the
‘Programming Guide’ in the following section for each parameter and its values.
Additional program notes:
1. The Bodyguard is capable to have two patterns (door closed and door open) that are independently
adjustable. Thus, when programming, it is necessary to adjust the pattern for door closed, and then to
adjust the pattern again when the door is open. The following functions may be independently adjusted
for each door position:
Sensitivity
Pattern Width
Pattern Depth
2. The following functions apply to both door closed and door open positions:
Automatic Learn Time
Immunity
Frequency
Output Configuration
Door Control Mode
Hold Time
Interface Type
3. The immunity modes include Medium (Rain) and High (Snow). During these modes, learn time of the
sensor will not be affected. These modes affect the interpretation of the objects in the field of detection
relative to the background.
4. MP mode set by the remote control, allows for a Besam MP Control specific setting. This setting is set
to a default of ‘0’ which allows Bodyguard to operate normally with any control, and when set to a
Besam specific setting of ‘1’ when used with a Besam MP control.