General Information
Section: General Information
Hazard De nitions
Within the boundaries of the hazard warning, there will
be information presented describing consequences if the
warning is not heeded and instructions on how to avoid
the hazard.
Indicates a hazardous situation,
which, if not avoided, will result
in death or serious injury.
Indicates a hazardous situation,
which, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation,
which, if not avoided, could
result in minor or moderate injury.
Intended to bring special attention
to information, but not related to
personal injury or property damage.
Owners Responsibility
Incorrect installation, adjustment, and
use of this burner could result in severe
personal injury, death, or substantial
property damage from re, carbon
monoxide poisoning, soot or explosion.
Contact a professional, quali ed service agency for the
installation, adjustment and service of your oil heating
system. This work requires technical training, trade
experience, licensing or certi cation in some states and
the proper use of special combustion test instruments.
Please carefully read and comply with the following
instructions:
Never store or use gasoline or other ammable
liquids or vapors near this burner or appliance.
Never attempt to burn garbage or refuse in this
appliance.
Never attempt to light the burner/appliance by
throwing burning material into the appliance.
Never attempt to burn any fuel not speci ed and
approved for use in this burner.
Never restrict the air inlet openings to the burner or
the combustion air ventilation openings in the room.
y
y
y
y
y
If the residence is unattended in severely cold
weather, burner primary control safety lockout,
heating system component failures, power outages
or other electrical system failures could result in
frozen plumbing and water damage in a matter of
hours. For protection, take preventive actions such
as having a security system installed that operates
during power outages, senses low temperature
and initiates an effective action. Consult with your
heating contractor or a home security agency.
Frozen Plumbing and
Water Damage Hazard
50 Hz Motors - The burner ratings,
air settings and nozzle ratings are
based on standard 60 Hz motors (at 3450 rpm). Derate
all ratings 20% when using 50 Hz motors. Consult
factory for speci c application data.
High altitude installation - Accepted
industry practice requires no derate
of burner capacity up to 2000 feet above sea level. For
altitudes higher than 2000 feet, derate burner capacity
2% for each 1000 feet above sea level.
Agency Approvals
UL certi ed to comply with ANSI/UL296 and
tested to CSA B140.0.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and must
be speci ed at time of order.