Datasheet

ACD-23SW ELECTRICAL SPECIFICATIONS
DC Volts
Ranges 400mV, 4V, 40V, 400V, 600V
Resolution 0.1mV
Accuracy ±(0.5% rdg + 2 dgts)
Input Impedance 400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ
Overload Protection 600V DC or AC rms to measure millivolts, use “RANGE “ button to manually select 400mV range
AC Volts (50Hz - 500Hz)
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy
±(1.2% rdg + 5 dgts)
±(2% rdg + 5 dgts) on 600V range
Input Impedance 4V:10MΩ;40V~600V:9.1MΩ
Overload Protection 600V DC or AC rms
AC Current (50Hz - 60Hz)
Ranges 40A , 400A
Resolution 0.01A
Accuracy ±(2.0% rdg + 10 dgts) 50 ~ 60Hz
Overload Protection 400A AC
Resistance
Ranges 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution 0.1Ω
Accuracy
±(1.0% rdg + 5 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 5 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open Circuit Volts -0.45V DC typical, (-1.2Vdc on 400Ω range)
Overload Protection 600V DC or AC rms
Capacitance
Ranges 4uF , 40uF , 400uF , 4mF
Resolution 1nF
Accuracy ±(3.0% rdg + 15 dgts)
Minimum Input Range >100nF
Overload Protection
600V DC or AC rms when the capacitor to be tested is connected, if “dsc” symbol is indicated on LCD, it means there is voltage
existing in the tested capacitor and needs to be discharged before testing.
Temperature
Ranges -30°F ~ 400°F, -35°C ~ 400°C
Resolution 0.1°F, 0.1°C
Accuracy
±(1% + 2°F) 32°F ~ 400°F ±(1% + 1°C) 0°C ~ 200°C
±(2% + 6°F) -30°F ~ 32°F ±(2% +3°C) -35°C ~ 0°C
Sensor Type K-type themocouple
Overload Protection 60V DC or 30V AC rms
www.beha-amprobe.com
For detailed specifications and ordering info go to www.beha-amprobe.com
©2014 Beha-Amprobe. All rights reserved.