User Manual

25
Overload protection: 1000 Vrms
600 Arms For ACD-50NAV, ACD-51NAV, ACDC-52NAV
1000 Arms For ACD-53NAV, ACDC-54NAV
Accuracy dened for:
Sine wave, ACA
10Arms, Freq. 50/60Hz
- Integration time about 100m seconds
(7) Active Power : Watt (DC/AC)
ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV
Function Range Accuracy
AC W / DC W
9.999KW**
A,error×V,reading+
V,error×A,reading
99.99KW
599.9KW / 999.9KW*
* ACD-50NAV, ACD-51NAV, ACDC-52NAV: 599.9KW
ACD-53NAV, ACDC-54NAV: 999.9KW
** The measured value<1.000kW, add 10 dgt to the accuracy.
Overload protection : 1000 Vrms
600 Arms For ACD-50NAV, ACD-51NAV, ACDC-52NAV
1000 Arms For ACD-53NAV, ACDC-54NAV
Accuracy dened for :
AC W :
Sine wave , ACV
10 Vrms, ACA 5 Arms
Freq. 50~60Hz, PF=1.00
DCW (For ACDC-52NAV, ACDC-54NAV only) :
DCV
10V, DCA 5 A
(8) Power Factor:
ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV
Function Range Accuracy*
PF -1.00 ~ 0.00 ~1.00 ±3°±1dgt
* ACA<100A, add ±2° to the accuracy (For ACD-50NAV, ACD-51NAV, ACD-
53NAV)
Overload protection : 1000 Vrms
600 Arms For ACD-50NAV, ACD-51NAV, ACDC-52NAV
1000 Arms For ACD-53NAV, ACDC-54NAV