User Manual

12
Battery Test
Applying a voltage source or incorrect battery type under battery test
may cause personal injury or damage to the Meter.
Battery 1.5V range is for dry battery not exceeding 2Vdc. The resistance load
is around 30Ω.
Battery 9V range is for dry battery not exceeding 15Vdc. The resistance load
is around 1KΩ.
SPECIFICATION
Ambient temperature: 23°C ±5°C (73.4°F ±9°F)
Relative temperature: 75%
Accuracy: ±(% of reading + digits)
Maximum voltage between input terminal and earth ground: AC 600Vrms or
DC 600V
Fuse for mA μA input: 0.5A H 660V fast-fuse, 6.3×32mm (AM-510)
0.5A H 700V fast-fuse,
6.3×32mm (AM-510-EUR)
Fuse for 10A input: 10A H 660V fast-fuse, 6.3×32mm. (AM-510)
10A H 600V fast-fuse, 6.3×25mm. (AM-510-EUR)
Maximum display: Digital 3999 counts, updates 3/sec. Frequency: 4999 counts.
Over-range indication: OL
Range: Automatic