TDS

TECHNICAL DATA SHEETTECHNICAL DATA SHEET
INTERIOR/EXTERIOR DIRECTTOMETAL SEMIGLOSS PAINT
NO. 3200 WHITE
Stain-Blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before topcoating the entire area. If bleeding
continues, primer may need a longer dry time before
applying topcoat.
Previously Painted Surfaces: Remove all loose and
peeling paint and all other foreign substances. Clean any
dirt and grease by scrubbing the surface with a detergent
and water solution, followed by a thorough rinsing with
clean water. Set nails and ll holes, scratches, and gouges
with the appropriate wood ller and let dry completely.
Remove all dust with a tack or wiping cloth. Fill all gaps with
a 100% acrylic, siliconized, paintable caulking, and allow to
completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the surface
thoroughly to provide a rough surface before coating
WARNING! If you scrape, sand or remove old paint, you may
release lead dust. LEAD IS TOXIC. Contact Lead Information
Center at 1-800-424-LEAD or log on to www.epa.gov/lead.
SYSTEM RECOMMENDATIONS:
Ferrous Metal
Self-prime using 2 coats of BEHR® Direct-To-Metal Interior/
Exterior Paint
or
1 coat BEHR Interior/Exterior Metal Primer No. 435
(recommended for optimal corrosion resistance or when
priming over sound rusty metal surfaces) or BEHR Multi-
Surface Interior/Exterior Stain-Blocking Primer & Sealer
No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Non-Ferrous Metal
1 coat BEHR Interior/Exterior Metal Primer No. 435 or BEHR
Multi-Surface Interior/Exterior Stain-Blocking Primer &
Sealer No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Drywall/Gypsum Wallboard
1 coat BEHR Drywall Plus Interior Primer & Sealer No. 73 or
BEHR Kitchen, Bath & Trim Interior Stain-Blocking Primer &
Sealer No. 75 (recommended for optimal enamel hold out)
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Wood
1 coat BEHR Multi-Surface Interior/Exterior Stain-Blocking
Primer & Sealer No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Masonry: Concrete, Cement, Brick, Stucco, EIFS
1 coat BEHR Multi-Surface Interior/Exterior Stain-Blocking
Primer & Sealer No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Concrete Masonry Units: Concrete Block, Cinder
Block, Split-Face Block
1 coat BEHR DRYPLUS® Masonry Waterproofer No. 875
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
Fiber-Cement
1 coat BEHR Multi-Surface Interior/Exterior Stain-Blocking
Primer & Sealer No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior
Paint Vinyl, PVC, Fiberglass, Architectural Plastics
1 coat BEHR Interior/Exterior Bonding Primer No. 432 or
BEHR Multi-Surface Interior/Exterior Stain-Blocking Primer
& Sealer No. 436
2 coats BEHR Direct-To-Metal Interior/Exterior Paint
NOTE: Certain substrate and exposure conditions, as well
as project requirements, may necessitate the use of other
substrate-specic or solution-driven primers.
PERFORMANCE DATA:
Accelerated Weathering (ASTM D4587 QUV-A)
Result: Pass - 1,000 hrs
Direct Impact Resistance (ASTM D2794)
Result: >160 in-lb
Adhesion (ASTM D4541; substrate - CRS)
Result: > 300 psi
Adhesion (ASTM D3359; substrate – aluminum)
Result: 5B
Abrasion Resistance (ASTM D4060; CS17 wheel, 1,000
cycles, 1 kg load)
Result: < 50 mg loss
Corrosion Resistance (ASTM G85; Annex #5, 1,000 hrs)
Result: Rating 10 per ASTM D714 for blistering
Rating 9 per ASTM D610 for rusting, less than 2 mm
rust creep from scribe
Flexibility (ASTM D522; 180° bend, 1/8” mandrel)
Result: Pass
Moisture Condensation Resistance (ASTM D4585;
100°F, 1,000 hrs)
Result: Pass
Pencil Hardness (ASTM D3363)
Result: HB
Block Resistance (ASTM D2793; aluminum, class III)
Result: B0
Mar Resistance (ASTM D5178; CRS)
Result: 4 kg
Chemical Resistance (ASTM D1308; 1 hr unless
otherwise noted)
Result: No lm defects when tested with the following
chemicals
50% Sulfuric Acid
25% Sodium Hydroxide
10% Hydrochloric Acid
5% Phosphoric Acid
Methanol
Aliphatic Hydrocarbon Solvent – 2 hrs
Motor Oil (10W30) – 2hrs
Vegetable Oil – 2 hrs
Salt Spray Resistance (ASTM B117; 200 hrs, with
primer)
Result: Rating 10 for blistering
Rating 5% for rust on the scribe
CLEANUP/DISPOSAL:
Clean all tools and equipment with warm, soapy water. Do
not dispose of this product down a drain. If spilled, contain
material and remove with an inert absorbent. Dispose of
contaminated absorbent, container and unused product
in accordance with all current federal, state and local
regulations. For recycling or disposal of empty containers,
unused product and soiled rags, contact your household
refuse collection service.
This information is provided “as is” and no representations or warranties, either express or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For SDS or to consult with a Behr Paint Company representative, call
1-800-854-0133 Ext. 2 (U.S.A. only). ©2023 Behr Process Corporation, Santa Ana, CA 92705 U.S.A.
Revised 4/2023
2 of 3