User Manual XENYX X1222USB Premium 16-Input 2/2-Bus Mixer with XENYX Mic Preamps & Compressors, British EQs, 24-Bit Multi-FX Processor, USB/Audio Interface and energyXT2.5 Compact BEHRINGER Edition Music Production Software behringer.
XENYX X1222USB User Manual Table of Contents Thank you........................................................................ 2 Important Safety Instructions....................................... 3 Legal Disclaimer.............................................................. 3 Limited Warranty............................................................ 3 1. Introduction................................................................ 5 1.1 General mixing console functions ..................... 5 1.
XENYX X1222USB User Manual Important Safety Instructions Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality commercially-available speaker cables with ¼" TS plugs pre-installed. All other installation or modification should be performed only by qualified personnel. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.
XENYX X1222USB User Manual [2] Subsequently, the product must be returned in its original shipping carton, together with the return authorization number to the address indicated by MUSIC Group. [3] Shipments without freight prepaid will not be accepted. § 4 Warranty Exclusions [1] This limited warranty does not cover consumable parts including, but not limited to, fuses and batteries.
XENYX X1222USB User Manual 1. Introduction FBQ Feedback Detection System The FBQ Feedback Detection System, integrated into the graphic equalizer, is one of the most outstanding characteristics of this mixing console. This ingenious circuitry lets you immediately recognize and eliminate feedback frequencies. The FBQ Feedback Detection System uses the LEDs in the frequency band faders of the graphic EQ to indicate the critical frequencies.
XENYX X1222USB User Manual 1.2 The user’s manual 2. Control Elements and Connectors The user’s manual is designed to give you both an overview of the controls, as well as detailed information on how to use them. In order to help you understand the links between the controls, we have arranged them in groups according to their function. This chapter describes the various control elements of your mixing console. All controls, switches and connectors will be discussed in detail. 1.
XENYX X1222USB User Manual LOW CUT 2.1.3 Aux sends (MON and FX) The mono channels of the mixing consoles have a high-slope LOW CUT filter for eliminating unwanted, low-frequency signal components (80 Hz, 18 dB/octave). GAIN Use the GAIN control to adjust the input gain. This control should always be turned fully counter-clockwise whenever you connect or disconnect a signal source to one of the inputs.
XENYX X1222USB User Manual PAN The PAN control determines the position of the channel signal within the stereo image. This control features a constant-power characteristic, which means the signal is always maintained at a constant level, irrespective of position in the stereo panorama. MUTE Use the MUTE switch to mute the channel. This means that the channel signal is no longer present in the main mix. However, the aux sends (MON and FX) remain active.
XENYX X1222USB User Manual MON SEND The aux send control MON SEND acts as master control for the monitor bus and determines the level of the summed signal that is taken from the mixer via the MON SEND connector and that can for example be fed to an amplifier for monitor purposes. Using the audio signal from this output, you can also feed a subwoofer if you don’t require stage monitors.
XENYX X1222USB User Manual This channel, intended especially for connecting stereo signal sources (CD players, DAT recorders or even sound cards) features a particularly practical feature: the VOICE CANCELLER. VOICE CANCELLER Here, you have a filter circuitry that lets you almost entirely remove the vocal portion of a recording. The filter is constructed in such a way that voice frequencies are targeted without majorly affecting the rest of the signal.
XENYX X1222USB User Manual Recording: For mastering, using a stereo compressor such as the COMPOSER PRO-XL MDX2600 can be recommended. Use it to custom-tailor the dynamic characteristics of your signal to the dynamic range of the recording equipment you are using. The signal is in this case passed on from the compressor into the recorder. PHONES The PHONES control adjusts the volume of the headphones connected to the PHONS/CTRL connector.
XENYX X1222USB User Manual FBQ FEEDBACK DETECTION PHANTOM The switch turns on the FBQ Feedback Detection System. It uses the LEDs in the frequency band faders to indicate the critical frequencies. On a per-need basis, lower the frequency range in question somewhat in order to avoid feedback. The graphic stereo equalizer has to be turned on in order to use this function.
XENYX X1222USB User Manual FOOTSWITCH Connect a standard footswitch to the footswitch connector; use this to switch the effects processor on and off. A flashing dot at the bottom of the display indicates if the effects processor is muted via the footswitch. ¼" TS footswitch connector strain relief clamp sleeve ◊ In chapter 4.2, you will find an illustration showing how to connect your footswitch correctly. tip sleeve pole 1/ground Fig. 3.
XENYX X1222USB User Manual Unbalanced ¼" TS connector Insert send return ¼" TRS connector Strain relief clamp strain relief clamp Sleeve sleeve ring Tip tip Sleeve (ground/shield) sleeve ground/shield ring return (in) tip send (out) Tip (signal) Connect the insert send with the input and the insert return with the output of the effects device. Fig. 4.3: ¼" TS connector Fig. 4.
XENYX X1222USB User Manual 5. Specifications Channels 9/10, 11/12 Mono inputs Microphone inputs (XENYX Mic Preamp) Type XLR, electronically balanced, discrete input circuitry Mic E.I.N. (20 Hz - 20 kHz) Stereo line inputs Type 2 x ¼" TRS connector, unbalanced Impedance approx. 40 kΩ @ 0 dB Gain Gain range -20 dB to +20 dB Max. input level +22 dBu @ 0 dB Gain @ 0 Ω source resistance -134 dB / 135.7 dB A-weighted @ 50 Ω source resistance -131 dB / 133.
XENYX X1222USB User Manual DSP Texas Instruments Converter 24-bit Sigma-Delta 64/128-times oversampling Sampling rate 40 kHz Audio Stereo In/Out Connector Type B Converter 16-bit Sample Rate 48 kHz USB Main mix system data Noise Main mix @ -oo, Channel fader -oo Main mix @ 0 dB, Channel fader -oo Main mix @ 0 dB, Channel fader @ 0 dB -99 dB -101 dB A-weighted -84 dB -87 dB A-weighted -80 dB -82 dB A-weighted Power supply Mains Voltage 100 - 240 V~, 50 - 60 Hz Power consumption 40
XENYX X1222USB User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION XENYX X1222USB Responsible party name: BEHRINGER USA, Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.: Phone: +1 425 672 0816 Fax: +1 425 673 7647 XENYX X1222USB complies with the FCC rules as mentioned in the following paragraph: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
XENYX X1222USB User Manual behringer.
XENYX X1222USB User Manual behringer.
behringer.