QTERM®-A12 TERMINAL HARDWARE MANUAL BEIJER ELECTRONICS 2212 South West Temple #50 Salt Lake City, Utah 84115-2648 USA M01-061-00 Rev 02 Phone 801-466-8770 Fax 801-466-8792 Email info@beijerelectronicsinc.com Web http://www.beijerelectronicsinc.
Copyright © 2011 Beijer Electronics. Printed in the USA. All rights reserved. No part of this publication may be reproduced, in any form or by any means without prior written permission from Beijer Electronics. Qlarity and QTERM are registered trademarks of Beijer Electronics. Microsoft, Windows, Windows NT, Windows 2000, Windows XP, Vista, ActiveSync and their respective logos are registered trademarks of Microsoft Corporation in the United States and other countries.
FCC Compliance Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Notes
CONTENTS CHAPTER 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 CHAPTER 2. SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 CHAPTER 3. APPLYING POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.1 Connecting to Earth Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.
Contents Notes ii QTERM-A12 Terminal
CHAPTER 1 INTRODUCTION The QTERM®-A12 is a rugged graphic human-machine interface terminal for use in a wide range of commercial and industrial applications. It has been designed with a robust set of industrial-grade features and options. • Windows® Embedded CE 6.
Introduction Notes 2 QTERM-A12 Terminal
CHAPTER 2 SAFETY SUMMARY The QTERM-A12 terminal is certified to operate at Temperature Code T6 in a Class I, Division 2, Group A, B, C and D hazardous environment. The terminal must be installed and operated as described in this document to meet this certification. All safety related regulations, local codes and instructions that appear in this manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it.
Safety Summary Notes 4 QTERM-A12 Terminal
CHAPTER 3 APPLYING POWER CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. Power is supplied to the QTERM-A12 terminal via the COM1 serial port connector or the 3-pin power terminal strip for input power, return and chassis ground. The QTERM-A12 may also be equipped with an optional Power-over-Ethernet (PoE) interface.
Primary Serial Port Connector for Power Input Applying Power lation between signal common and earth ground, care must be taken when connections are made to the terminal. For example, a power supply with isolation between its signal common and earth ground must be used. Also, plugging in a serial cable or a USB cable may connect signal common and earth ground. The serial cable shield or the USB shield may be connected to earth ground at the host.
Applying Power Optional Power-over-Ethernet Interface 3.4 Optional Power-over-Ethernet Interface WARNING Although the terminal includes protection circuitry to prevent power supply contention, power should not be connected to the 3-pin terminal strip or the DB9 connector while power is applied to the RJ45 PoE interface. The QTERM-A12 may be equipped with an optional Power-over-Ethernet (PoE) interface.
Powering On the Terminal for the First Time Applying Power 3.5 Powering On the Terminal for the First Time When you connect power to the QTERM-A12 terminal, the operating system is automatically loaded. The QTERM-A12 takes 10 to 20 seconds to boot. During that time the backlight of the display will come on to indicate that the terminal is booting.
CHAPTER 4 HARDWARE DESCRIPTION AND ARCHITECTURE 4.1 User Interface Display The QTERM-A12 features a TFT color SVGA (800 x 600 pixels) LCD display that measures 308 mm (12.1") diagonally. The display backlight has a typical rating of 450 nit. Touch Screen A clear analog-resistive touch screen covers the entire display area for user input. The touch screen is a 5-wire architecture offering improved durability and touch endurance.
Serial Communications Hardware Description and Architecture 4.4 Serial Communications CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The QTERM-A12 has two serial ports, designated COM1 and COM2, that can communicate up to 3.6 MBaud. Refer to section 7.2, “Connector Pinouts” for serial port pinout data.
Hardware Description and Architecture Power Supply 4.7 Power Supply CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The QTERM-A12 has a 10- to 32-volt DC input range and can be powered directly from a 12or 24-volt DC power supply. The terminal includes circuitry to protect against normal variations such as transients and spikes (EN55024 compliant), as well as reverse voltage and overvoltage protection.
Housing Hardware Description and Architecture Notes 12 QTERM-A12 Terminal
CHAPTER 5 INSTALLATION A QTERM-A12 terminal uses a rugged chemical resistant polymer housing and mounting components. When properly installed in a NEMA-4X rated panel, the QTERM-A12 meets all NEMA-4X specifications including hose-down, icing and salt spray. A QTERM-A12 terminal can be installed in either a landscape or portrait orientation. In addition, the terminal can be installed with or without a front bezel.
Cutting Out for Panel Mount Installation 5.1 Cutting Out for Panel Mount 5.1.1 Standard Version Cutout The standard version cutout is to be used with QTERM-A12 models that have a factoryinstalled front bezel. The standard QTERM-A12 terminal can be mounted in panels from 0.8 to 10 mm thick. No screw holes need to be drilled to install the terminal in the panel. Make a rectangular hole in the panel using the following dimensions. Landscape Portrait Horizontal: 302.5 ± 1 mm Horizontal: 254.
Installation 5.1.2 Cutting Out for Panel Mount Modular Version Cutout The modular version cutout is to be used with QTERM-A12 models that DO NOT have factory-installed front bezels. The modular version of the QTERM-A12 terminal can be mounted in panels with any thickness. In addition to making a cutout in the panel, the panel must be fitted with mounting studs. Make a rectangular hole in the panel using the following dimensions. Landscape Portrait Horizontal: 248.0 ± 1 mm Horizontal: 187.
Installing the Terminal Installation 5.2 Installing the Terminal WARNING When mounting the QTERM-A12 terminal within a final enclosure, make sure you provide adequate ventilation: a minimum of 51 mm (2.0 inches) around the back, sides and bottom and 77 mm (3.0 inches) clearance above the top of the QTERM-A12 terminal. CAUTION This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only.
Installation Installing the Terminal • Portrait When looking at the front of the unit, the back panel serial port(s) should be facing left. Refer to Figure 3 for an example of a landscape installation. Figure 3 QTERM-A12 Mounting 3. On the back of the panel, align the terminal mounting ring holes with the mounting studs, and place the mounting ring against the back of the panel. Refer to Figure 3 for the location of the mounting studs. 4.
Installing the Terminal Installation the back panel may indicate the orientation. If not, you can determine which side should be at the top by the position of the serial port(s) on the back panel as follows: • Landscape When looking at the front of the unit, the back panel serial port(s) should be facing down. • Portrait When looking at the front of the unit, the back panel serial port(s) should be facing left. Refer to Figure 4 for an example of a landscape installation.
CHAPTER 6 SPECIFICATIONS DISPLAY Color TFT color SVGA LCD display 65,536 colors Size 308 mm (12.1") diagonal 246 mm x 184.5 mm active area Pixels 800 x 600 (SVGA) Dot pitch 0.3075 x 0.
Specifications PHYSICAL STANDARD VERSION (WITH FACTORY-INSTALLED BEZEL) Dimensions 344.4 (W) x 267.0 (H) x 69.1 (D) mm Mass 2.05 kg MODULAR VERSION (WITHOUT FACTORY-INSTALLED BEZEL) Dimensions 298.9 (W) x 252.6 (H) x 62.8 (D) mm Mass 1.
Specifications MEMORY DDR SDRAM 128 Mbytes standard, 16 bit wide bus, 130 Mhz => 520 Mbytes/s transfer rate Non-volatile storage 4 Gbytes standard SOFTWARE Operating system Microsoft Windows Embedded CE version 6.0 R3 Professional CERTIFICATION FCC Part 15, Class A CE Certification EN-55022, EN-55024 and EN-60950 UL Listed by Und. Lab. Inc. To U.S.
Specifications Notes 22 QTERM-A12 Terminal
CHAPTER 7 MECHANICAL 7.1 Layout and Dimensions 7.1.1 Standard Version The standard version of the QTERM-A12 is equipped with a factory-installed front bezel. The front bezel has molded-in studs that are used together with a terminal ring to mount the terminal to a panel.
Layout and Dimensions Mechanical Figure 6 QTERM-A12 Back View (units: mm) Figure 7 QTERM-A12 Bottom View (units: mm) 24 QTERM-A12 Terminal
Mechanical Layout and Dimensions Figure 8 QTERM-A12 Side View (units: mm) QTERM-A12 Terminal 25
Layout and Dimensions 7.1.2 Mechanical Modular Version The modular version of the QTERM-A12 does NOT have a front bezel. Mounting studs must be integral to the panel where the QTERM-A12 will be mounted. The modular version allows installers to use their own custom bezel or to use the panel as the bezel.
Mechanical Layout and Dimensions Figure 11 Modular QTERM-A12 Bottom View (units: mm) Figure 12 Modular QTERM-A12 Side View (units: mm) QTERM-A12 Terminal 27
Connector Pinouts Mechanical 7.2 Connector Pinouts 7.2.1 Primary Serial Port CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The following table shows the pinouts for each type of serial interface on the primary serial port.
Mechanical 7.2.2 Connector Pinouts Secondary Serial Port CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The secondary serial port on the QTERM-A12 is configured as EIA-232 only with hardware or software handshaking. The pins are defined below. 1 2 3 4 5 6 7 8 9 7.2.
Connector Pinouts 7.2.4 Mechanical Ethernet Port CAUTION For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The Ethernet port has a standard 10/100Base-T interface with an 8-pin (RJ-45) modular jack connector. The connector orientation and pinout table are shown below. For PoE pinout information please refer to section 3.4, “Optional Power-over-Ethernet Interface”.
Mechanical 7.2.5 Connector Pinouts USB 2.0 Ports CAUTION CAUTION For Class I, Division 2 installations: The USB ports are for operational maintenance only. Do not leave USB devices permanently connected unless the area is known to be non-hazardous. For Class I, Division 2 installations: Do not connect or disconnect cables while power is applied unless the area is known to be non-hazardous. The QTERM-A12 includes two USB 2.0 full-speed ports. The connector orientation and pinout table are shown below.
Connector Pinouts Mechanical Notes 32 QTERM-A12 Terminal