Operation Manual

- C 45 -
Short Seam Automat 2211-5 Working Instructions Beisler Automated Sewing Equipment
C.5
Maintenance
WARNING - Electric shock!
Contact with current-carrying components may cause
a lethal electric shock.
As moving parts of the machine may catch and wind
up loose clothing if the machine is put in motion ac-
cidentally, make sure to stay away from the operating
range of the machine to avoid injuries.
Prior to any service, cleaning or maintenance works,
disconnect the machine from the power supply sy-
stem!
Turn the machine off using the main switch.
Remove power plug from socket and protect it from
accidental reconnection.
If the power supply is not required for repair or set-
up work, the machine must be disconnected from
the power supply system.
C.5.1 Inspection
The machine must be inspected annually.
The inspection comprises particularly the following items:
safety devices of the machine,
operativeness of the program control,
correct function of inputs and outputs.
C.5.2 Cleaning
The machine must be cleaned after large production se-
ries, or at least once a day, whichever occurs first.
Cleaning the machine surfaces:
1. Disconnect machine from power supply system.
2. Remove fabric residues.
3. Using compressed air, blow off dust and thread resi-
dues at the sewing head, at the working plate, at the
clamp and at the linear rail.
4. Wipe machine parts dry using a dry, clean cloth.
NOTE - Plastic surfaces!
Some parts of the machine surfaces are made of plas-
tic materials. Solvents may dissolve plastics and make
them unusable.
Do not clean the machine surfaces (particularly the
operating panel) with cleaning agents that contain
solvent.