Operation Manual

- C 67 -
Short Seam Automat 2211-5 Working Instructions Beisler Automated Sewing Equipment
C.6
Troubleshooting
Error 32:
„Thread position does not
come
During thread cutting, sewing motor did not
reach cutting position
Input slower cutting speed and earlier
cutting position; replace sewing motor or
synchronizer
Error 33:
„Sewing motor does not
stop“
After thread cutting, sewing motor does not
stop within error period
Input slower cutting speed and earlier
cutting position; replace sewing motor or
synchronizer
Error 34:
„Needle not up“
Needle not in upper rest position; when the
error message is issued, the control unit
attempts once more to move the needle to
the upper position
Check sewing motor and synchronizer;
check connection between 9020013 and
sewing motor; read condition of two upper
LEDs at 9020013: if no LED illuminates
when handwheel is rotated, check sewing
motor power supply; replace sewing motor
if required; if LEDs are OK, check
connection between 9020020 and sewing
motor; replace 9020020 if required
Error 35:
„Thread breakage“
Thread monitor detects thread breakage
Error 37:
„Thread only rest
The photocell at the spool case is
illuminated, spool empty
If spool is not empty, the photocell is
maladjusted (response too sensible); adjust
correctly
Error 41:
„No parts
Photocell FZ21 remains illuminated during
insertion
Adjust photocell sensibility; input test 21
Error 42:
„Photocell not lighted“
Photocell FZ21 does not detect end of
seam
Sewing distance too long; adjust photocell
sensibility; input test 21
Error 43:
„Photocell lighted too early
Photocell FZ21 detects intermittent
reflection during insertion
Adjust photocell sensibility; input test 21
Error 45 ... 48:
“I/O DAC, ULN, 485, RES
Internal hardware error during data
transmission to adapter board 9020020