Operation Manual

- D 87 -
Short Seam Automat 2211-5 Working Instructions Beisler Automated Sewing Equipment
D.3
Programming
D.3.7 List of global parameters
No. Programmable global parameters (F2)
01
TILL CLAMP SIDEWAYS FWD:
Scan and part pickup after clamp movement forward / time interval
02
TILL CLAMP DOWN ......:
Lower clamp after clamp movement forward for part pickup / time interval
03
TILL VACUUM OFF ......:
Switch vacuum off after clamp down / time interval
04
THRD LENGTH,BOBBIN FULL
Length of thread of filled bobbin
05
TILL CLAMP INSERTING:
Clamp insertion delay / time delay
06
SEWING END ->CL.SIDEW.:
Clamp movement sideways rearward after sewing is completed / time interval
07
TIME AFTER CLAMP OPEN :
Clamp movement right to programmed position after clamp up / time interval
10
TILL FOLDING CL. CLOSED:
After folder right and down, tim e until folding clam p closes / tim e interval
11
TILL FOLDER LIFT UP...:
After folding clam p closes , tim e until folder up / tim e interval
12
TILL FOLDER SWINGS LEFT:
After folder up, time until folder swings left and rotates / time interval
13
IMPULS FOLDER DOWN ...:
Pulse duration folder down, time until folder is switched airless during pick-up / time delay
14
CL.OPEN TILL FOLDER UP:
After folding clamp opens, time until folder up / time interval
17
TILL TENSION OPEN ....:
After end of seam, time until tension blower on / time interval
18
DURATION OF TENS. OPEN:
ON duration for tension blower
19
TILL THREAD CLAMP FORW.:
After clamp up, time until thread clamp forward / time interval
20
DUR.THREAD CLAMP FORW.:
Duration of blowing and thread clamp forward
21
TILL STACKER TRANSPORT:
After sewing drive stops and transport stamp down, time until stacker transport moves backward to ES8 / time
interval
22
DUR.SLIDING TABLE OPEN:
Duration for sliding table open / time delay
23
LIFT.TABLE MOD 00/01-99:
Lower lift table, defaults:
Input 00: Lower lift table using photocell control
Input 01-99: Lift table is lowered after corresponding number of pieces
24
DUR.LIFTING TABLE SINKS:
Lower lift table / duration
25
TILL FABRIC CLAMP FORW.:
After footswitch is released, time until pocket bag clamp closes / time interval