Data Sheet

Type RJS
Telecom
-
Power
Cross Protection & Ballast Protection
belfuse.com/
circuit
-
RJS Series
RoHS 2
Compliant
Description
RJS Fuses are primarily intended for use in telecommunication circuit applications
requiring low current protection
with high surge tolerance.
They are typically used to
replace heat coil type devices. They are de
signed to be placed
between the line input
and the surge arresting components (mov. gas tube, zenor diode, air gaps, etc
.
)
T
hese fuses will withstand transient surge currents generated by lighting in
accordance wi
th the attached table
.
RJS fuses guard protected circui
try
against sustained overload or short cir
cuit
conditions. Such sustained
overl
oads may be generated by accidental
contact
betw
een utility
cables and phone lines (power line cross
).
RJS Fuse are
primarily designed for use in telecommunications circu
its which
require compliance with the test
requirements specified in UL
/
IEC 1950/60950 and
Telcordia GR 1089, Issue 3
Features
-
Radial lead surge resistant slow blow fuse
-
Meet UL 60950 power
cross requirements
-
Designed for compliance with Telcordia GR
-
1089
-
CORE
-
Designed to serve the requirements of a wide range of telecommunication and
networking equipment
-
RoHS
2
compliant
-
Halogen Free
-
Leadfree
Applications
-
Fax machines
-
Answering machines
-
Telecommunication circuit
LEAD FREE =
-
Ballast protection
HALOGEN FREE =
Physical Specifications
Electrical Characteristics
Safety Agency Approvals
(UL/CSA STD.
248
-
14)
Materials
Body :
Glass
Leads
: Matte Tin Plated Copper
,
Diameter 0.032
"
Marking
On Fuse :
bel
”, “
R
JS
”,
Current Rating”, “Voltage Rating”,
“Appropriate Safety Logos”,
RoHS
2
compliant
On Label :
"bel", "
RJS”
, "Current Rating", "Voltage Rating",
"Interrupting Rating",
"Appropriate Safety Logos" and "
", "
"(China RoHS compliant).
Safety
Agency
Safety
Agency
Certificate
Power
Factor
Voltage
Rating
(V)
Ampere Range / Volt
@ I.R. ability*
Intended
Application
E20624
0.7
-
0.8
100
m
A
-
5V/
600V AC
100
mA
-
5A/125V AC@10.000A
General Purpose
0.7
-
0.8
100
mA
-
5A/250V AC@200A
Primary Protection
LR39772
R
esistive
100
mA
-
5A/350V AC@100A
Ballast Protection
R
esistive
100
mA
-
5A/600V AC@60A
Tele
com Protection
R
esistive
100
mA
-
5A/600V AC@100A
General Purpose
Telecom Pr
o
tection
*I.R.= Interrupting Rating = Short Circuit Rating(Amps)
Testing
Current
Blow Time
Minimum
Maximum
100%
4
hrs
.
N/A
135%
N/A
1
hr
.
200%
3
sec
20 sec
500%
100
msec
1.5 sec
1000%
30 msec
300 msec
Spe
cifications subject to change without notice