Install Instructions

21
Tech.Doc - 03/21 - Subject to change. © Belimo Aircontrols (USA), Inc.
ZIP Economizer
Menu Sequence Documentation
ZIP Code
xxxxxx
OK
esc
(5)
Sub menu
(6)
US
xxxxx
Canada
xxxxxx
(1)
Only present if device is connected and functioning.
(2)
Only present after setup has been completed, else navigation jumps
over this menu.
(3)
Only one value displayed at a time.
(4)
Unit depends on selected temperature scale and is auto selected by
US / Canada, ZIP/Postal code, (°F & Btu/lb or °C & kJ/kg).
(5)
Press esc button from any sub menu item.
(6)
Press OK to change a setting on lowest menu level into editing mode.
(7)
Only present during initial setup- see menu table for additional
information
(8)
Only visible when Purge Enable is On.
(9)
Only displayed with enthalpy configurations.
(10)
SAT Setpoint control only valid when in Free Cooling Mode.
(11)
Only present when Energy Module connected
(12)
Present when ALM IF Alarm selected.
(13)
MP Bus is default communication protocol.
(14)
BACnet Device ID can be between 0-4194303
Compressor Qty
auto
(3)
1
(3)
2
(3)
Exh Fan Install
auto
(3)
not installed
(3)
installed
(3)
OAH Sensor
Auto
(3)
not installed
(3)
installed
(3)
RAH Sensor
auto
(3)
not installed
(3)
installed
(3)
DCV Min Pos
(1)
xxx%
DCV PPM Set Pnt
(1)
xxxxppm
Low Sp Vent Min
(1)
xxx%
Low Sp DCV Min
(1)
xxx%
Low Exh Fan Pos
(1)
xxx%
Temp Unit
°F
(3)
°C
(3)
Purge Enable
On
(3)
Off
(3)
SAT Y2 Limit
On
(3)
Off
(3)
Purge Dmp Set
(8)
xxx%
High Limit
Modification
(1)
Heat Pump Op
Off
(3)
HP(O)=pow=Cool
(3)
HP(B)=pow=Heat
(3)
HP(W1)=pow= Heat
(3)
4
Status line
Monitor Live
Conditions
Settings
Present Devices Alarm
esc
esc
esc
esc
Any key
esc
Service and
Commissioning
(2)
esc esc esc escesc
Energy Module
(11)
I/O Config
esc
OK
Vent Min Pos
xxx%
Exh Fan On Pos
xxx%
esc
OK
esc
OK
DCV
available
(3)
Not detected
(3)
esc
OK
LCLO Limit
xx°F
xx°C
SAT Setpoint
(10)
xx°F
xx°C
Remote Dmp Cntrl
On
(3)
Off
(3)
Economizing
disabled due to
sensor error
(3)(4)
Fixed dry bulb
Differential dry bulb
Fixed enthalpy +
Fixed dry bulb
Diff enthalpy +
Fixed dry bulb
High Limit
(3)(4)
xx°F
xx°C
xx.xBtu/lb
xx.xkJ/kg
High Limit
(3)(4)(9)
xx°F
xx°C
OK
esc
ALM IF Set To
(11)
2 Speed Fan Op
Alarm
esc
OK
Devices
CC1
(1)
CC2
(1)
EF
(1)
IF
(1)
Humidity Sensors
OAH (Yes/No)
RAH (Yes/No)
2 Speed Fan Op
(12)
Off
On
Fan 2Speed
auto
(3)
not installed
(3)
installed
(3)
Com interface
(13)
MP active
Com Selection
MP active
BACnet active
OK
esc
OK
esc
Baudrate
115200
76800
57600
38400
19200
9600
BACnet Device ID
(XXXXXXX)
(14)
MS/TP Address
(XXX)
Device Name
(RTU_XXX)
Device Name
(RTU_XXX)
Location
(Bldg_XXX)
BACnet Com State
not OK
OK
Settings