DDEX Installation Guide

Page 5
Downdraft Ventilators
PLAN THE WIRING
Interior Blower Installation
Exterior or In-Line Blower Installation
1. The Exterior or In Line Downdraft Blower system draws 6
AMPS and requires a 120 VAC, 60 Hz circuit.
2. The unit has a 18 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit’s power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Model DDEX30SS is being installed in a 30" wide
cabinet...
o r Model DDEX36SS is being installed in a 36" wide
cabinet...
o r Model DDEX48SS is being installed in a 48" wide
cabinet...
...the outlet cannot be located on the back
wall of cabinet.
In these cases, the width of the downdraft covers nearly
the entire width of the back wall of the cabinet. So you
must either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the down
draft. Then provide a clearance hole in the back wall
of the cabinet.
1. The Interior Downdraft Blower system draws 4 AMPS and
requires a 120 VAC, 60 Hz circuit.
2. The unit has a 18 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit’s power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Model DD0130SS is being installed in a 30" wide
cabinet...
o r Model DD0136SS is being installed in a 36" wide
cabinet...
o r Model DD0148SS is being installed in a 48" wide
cabinet...
...the outlet cannot be located on the back
wall of cabinet.
In these cases, the width of the downdraft covers nearly
the entire width of the back wall of the cabinet. So you
must either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind
the cabinet - where it will not be covered by the
downdraft. Then provide a clearance hole in the
back wall of the cabinet.
PREPARE THE DOWNDRAFT
Blower Duct Connection Installation (all blowers)
The downdraft is shipped with duct connector pointing toward the
bottom of the unit. If you wish to change this orientation, follow
the steps below:
1. Place the downdraft on its back on a table of flat work surface.
2. Remove the 4 nuts and 2 clamp channels.
3. Remove 2 screws and the gear motor cover.
4. Carefully position the blower under the bottom flange of
the downdraft with the 3¼" x 10" discharge (3¼" x 14" for
exterior or in-line blower) pointed in the desired direction.
5. Connect motor plug.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
tighten.
8. Slide blower left of right to desired position. Use cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws
(supplied) through bottom flange to secure bottom in blower.
NUTS
BLOWER
COVER
PLATE
CLAMP
CHANNELS
SCREWS
GEARMOTOR
COVER
MOTOR
PLUG
3¼" X 10" DISCHARGE
(3¼" X 14" FOR EXTERIOR OR IN-LINE BLOWER)