DDEX Installation Guide

Page 8
Downdraft Ventilators
INSTALL ELECTRICAL WIRING
Interior Blower Installation
1. Mount a standard wiring box, with 3-pronged receptacle, inside
the cabinet. Make sure the downdraft's power cord can easily
reach it.
2. Run appropriate power cable into cabinet and connect it to
receptacle.
3. Plug the downdraft's power cord into the outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
!
CAUTION: All electrical wiring should be done
by a qualified person(s) in accordance with all
applicable codes and standards.
Exterior or In-Line Blower Installation
1. Mount a standard wiring box, with 3-pronged grounded recep-
tacle, inside the kitchen cabinet. Make sure the unit's power
cord can easily reach it.
2. Run appropriate power cable into cabinet and connect it to
electrical box and receptacle.
3. Exterior or in-line blower may not exceed 6.0 Amp rating.
4. Run 2-wire plus ground power cable from the exterior or in-
line blower to wiring box on adaptor plate. Remove wiring box
cover.
5. Connect wiring harness to power cable from exterior or in-line
blower. Wire black to black, white to white, and green to green
or bare wire.
6. Replace wiring box cover.
7. Plug the downdraft's power cord into outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
!
CAUTION: All electrical wiring should be done
by a qualified person(s) in accordance with all
applicable codes and standards.
INSTALL COOKTOP
All Units
1. Align the cooktop with the downdraft and fasten cooktop in
place.
Note: Accurate alignment of cooktop and downdraft is necessary
to ensure that there is no interference when air vent is raised and
lowered. There should be a gap of 1/32" - 1/16" between the back
of the cooktop and the front of the downdraft cover.
Note:
The downdraft up/down control must be mounted into the coun-
tertop, at least 4" from the cooktop.
COUNTERTOP
UP / DOWN
CONTROL
COOKTOP