Operation Manual

BFB-3000 Set Up and Operations Manual
Document No: D100253 37
6.9.2 Extruder control
Make sure all extruders are loaded.
Use ‘Manual move’ (page 18) to move the extruders to the centre of the machine,
and lower the bed. This makes it easy to clean any purged material.
On the control panel select the ‘Extruder control’ function and press enter:
RUN FILE
EXTRUDER MAPPING
MANUAL MOVE
>
EXTRUDER CONTROL
HOME TOOL HEAD
SETTINGS
‘Extruder control’ manages one extruder at a time (E1, E2 or E3) using the buttons on
the control panel.
EXTRUDER CONTROL
Cur
Tgt
RPM
E3
E2
25C
0C
0
>
E1
259C
*
260C
0
“>” indicates
selected extruder
E1, E2 or E3 are
selected using
the Z buttons
Temperature
at extruder
nozzle (°C)
Target
temperature
at extruder
nozzle (
°C).
Use Y buttons
to change.
Revolutions per
minute for the
extruder drive
screw. Use X
buttons to
change.
Extruder motor
will not turn until
target
temperature has
been achieved.
*” indicates
extruder is being
heated.