User's Manual

SERVICE
9
Hydraulic Fluid Levels
1. Remove cover from hydraulic pump. Check
fluid level in hydraulic reservoir.
2. Lower trailer deck. If oil level is below 3 inches
with deck down, add 1/2 quart of hydraulic oil.
Use BP type HLP-46 or 10w hydraulic oil.
NOTE: When trailer deck is raised, hydraulic
fluid level should be at least 1/2 of reservoir
volume.
3. Remove fill cap from surge brake reservoir.
Add DOT 3 brake fluid as needed to bring
fluid level to 1/2-inch below fill port.
25/16
B
ALL
FILL CAP
Battery
1. Use hydrometer to check battery charge daily
or weekly, depending on frequency of use. If
the battery charge drops below 25% of full
charge (S.G. below 1.155 as corrected to
80°F) the battery must be recharged. Refer to
step 2 before charging battery.
3. Charge battery at one of the following charge
rates. The slow charge rate is preferred.
22 hours @ 5 amps
25 hours @ 20 amps
22 hours @ 50 amps
2. Check the electrolyte level weekly. If battery
charge is low, add water to bring electrolyte
level just above plates.
If battery is fully charged, add water to raise
electrolyte to full mark in each cell.