Operation Manual
6
several times until the timer active icon
J
goes out.
You may also cancel the timer by turning the unit off
using the on/off button
F
.
CLEANING THE FILTERS
We recommend regular lter cleaning for optimal
performance.
• Every few weeks, check the condition of both
lters.
• After approximately 3 months of operation, the
lter service indicator icon
K
will appear on
the LCD display to alert you to clean the lters
before further use.
• Depending on use, the lters should be
replaced after approximately 12 months.
Pre-lter
If you are replacing the lter, remove any packaging
from the new lter before tting.
1. Switch off and unplug your air purier from the
supply socket.
2. Referring to gure 2, press the rear grille latch
S
down and remove the rear grille
T
.
3. Remove the pre-lter
U
from the inside of the
rear grille.
4. Wash the pre-lter in warm soapy water.
5. Allow the lter to dry naturally on a at surface.
6. Once thoroughly dry, ret the pre-lter into the
rear grille then replace the rear grille onto your
air purier.
HEPA-type lter
If you are replacing the lter, remove any packaging
from the new lter before tting.
IMPORTANT: Do not use water, household puriers
or detergents to clean the lter. The lter may appear
discolored, even after vacuuming. This is normal and
does not affect performance in any way.
1. Switch off and unplug your air purier from the
supply socket.
2. Referring to gure 2, press the rear grille latch
S
down and remove the rear grille
T
.
3. Remove the HEPA-type lter
V
from your air
purier.
4. Using your vacuum cleaner, run the brush
attachment along both sides of the lter and
clean between the pleated layers.
5. After cleaning, ret the HEPA-type lter then the
rear grille.
Resetting the lter service indicator icon
1. With your air purier switched on, reset the lter
service indicator icon
K
by inserting a small
object (such as a pin or paper clip) into the
hole for the lter reset button
A
until the lter
service indicator icon goes out.
TROUBLESHOOTING
Problem Solution
The unit will not
operate
• Make sure that the unit is
plugged in and switched
on
Decreased air ow • Make sure that nothing is
blocking the air inlet or air
outlet.
• Check the condition of the
lters and clean them if
necessary.
• Make sure that the air
intake grill is at least 30 to
90 cm from the wall.
Filter appears dirty,
even after vacuum-
ing clean
This is normal and does
not affect performance in
any way. A new lter is not
necessary.
The lter service
indicator icon is still
on after cleaning
the lters.
See the Resetting the lter
service indicator icon section
in these instructions.
TECHNICAL SPECIFICATION
For all technical and regulatory information with
regards to your product specications under Eco-
Design Regulation No 206/2012, please contact our
consumer help line or visit www.bionaireuk.co.uk.
SPARE PARTS
HEPA-type lter 91382
Pre-lter 91383
UK - Filter Sales Order Line - 0870 759 9000