INSTALLATION, OPERATION & MAINTENANCE MANUAL R & RX SERIES TOP DISCHARGE Electric Submersible Pumps Single Phase 115V & 230V Three Phase 230V & 460V CAST IRON SINGLE PHASE R100 R250 R400 R400D R400P R750 R1500 R1520 R1530 THREE PHASE R08 R15 316 STAINLESS STEEL SINGLE PHASE RX750SS RX1500SS THREE PHASE RX08SS RX15SS Read this manual carefully before installing, operating or servicing these pump models. Observe all safety information.
TABLE OF CONTENTS INTRODUCTION............................................................................................................................................................ 4 SAFETY ......................................................................................................................................................................... 5 INSPECTION .....................................................................................................................................
INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassembly, assembly and testing of the BJM Pumps® R & RX Series submersible pump. This manual also contains information to optimize performance and longevity of your BJM Pumps submersible pump. The submersible R Series pumps are designed to pump water. The RX Series pumps are designed to pump corrosive liquids in concentrations chemically compatible with 316SS and FKM.
SAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the owner/service mechanics responsibility to repair, service, and test to ensure that the pump integrity is not compromised according to this manual. Risk of electric shock – this pump has not been investigated for use in swimming pool areas. Do not pump flammable, inflammable or volatile liquids. Death or serious injury will result.
INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. If there are questions in regards to your specific application, contact your local BJM Pumps distributor or BJM Pumps, LLC. PRE-INSTALLATION INSPECTION 1) 2) 3) 4) 5) Check the pump for damage that may have occurred during shipment. Inspect the pump for any cracks, dents, damaged threads, etc. Check power cord for any cuts or damage.
PUMP INSTALLATION R & RX Series pumps have been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information. Risk of electric shock. Pump models; R100, R250, R400, R400D, R400P, R750 & RX750 (115v) are supplied with a grounding conductor and grounding-type attachment plug. Pump models; R1500, R15, R08, RX08SS & RX15SS do not come with electric plug connectors.
PUMP ROTATION Two ways to check the correct pump rotation: 1. By looking at the impeller; the rotation of the impeller should be counter clockwise as shown in the picture below. 2. By looking from the top of the pump. Since the impeller cannot be seen, the best way to check the rotation is to check the kick back motion of the pump when the pump just starts. The kick back motion of the pump should be counter clockwise as shown in the picture below.
PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump any liquids which may damage the pump or endanger personnel as a result of pump failure. Do not operate this pump where explosive vapors or flammable material exist. Death or Serious injury will result. TYPICAL MANUAL DEWATERING INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour.
STOPPING To stop the pump (manual and automatic mode), unplug it from the power source, turn off the breaker, or turn the power source off (generator). Typical 3 phase manual control 1 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour. AUTOMATIC OPERATION Float switches (wired into the pump motor or piggy-back style) are available from the factory as an option.
Note: 230V & 460V pumps do not have a plug installed. Three phase pumps need a separate control box with float(s) for automatic operation. STOPPING To stop the pump (manual and automatic mode), unplug it from the power source, turn off the breaker, or turn the power source off (generator). INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied with a three prong grounded plug to help protect you against the possibility of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN. The three prong plug must be inserted into a mating three prong grounded receptacle.
Typical 3 phase Auto Control 1 Before installing a pump, check the pump rotation to insure that wiring has been connected properly to power source, and that the green lead of power cord (See wiring diagram), is connected to a valid ground, momentarily energize the pump, observing the directions of kick back due to starting torque. Rotation is correct if kick back is in the opposite direction of rotation arrow on the pump casing.
PUMP WILL NOT RUN 1. 2. 3. 4. 5. 6. 7. Check power supply (fuses, breaker). Reset power. Blocked impeller. Remove strainer, check and clean. Defective cable or incorrect wiring. Strainer clogged. Check and clean as necessary. Float switch tangled/obstructed. Clean and free float switch from obstruction. Float switch defective. Replace float switch. Pump overheated or temperature of liquid exceeds pump operating temperature.
More frequent inspections are required if the pump is used in a harsh environment. Preventative maintenance should be performed to reduce the chance of premature failure. Worn impellers and lip seals should be replaced. Cut or cracked power cords must be replaced. (Never operate a pump with a cut, cracked or damaged power cord.) Seal oil should be checked once per year. Maintenance should always be done when taking a pump out of service before storage.
EXPLODED VIEW OF R100 16
EXPLODED VIEW OF R250, R400 & R400D, R400P 17
EXPLODED VIEW OF R750, RX750SS, R1500, RX1500SS, R1520 & R1530 18
EXPLODED VIEW OF R08, RX08SS, R15, RX15SS 19
R SERIES PARTS LIST Pos. No. 01 D01 D01-1 01-2 D01-2,3,4,5 03 04 05 05 06 07 07-1 08 08-1 09 09 09 10 13 13 14 16 16-1 17 17 17 18 18 18 18 18 19 20 21A 21A-1 21B 23 23 23 23 Part Description Strainer Bottom Plate w/ Rubber Strainer - solid, R400D only Bottom Plate Non-Return Valve Assembly Impeller Nut Lock Washer Impeller Cast Iron Impeller: Fiberglass Reinf.
23 23 24 24 26 26-1 27 27 27 27-1 27-2 31E 32 34 35 38 38 38 38 38F 38F 50-01 50-01-2 50-01-3 50-07 50-08 50-11 50-11-1 50-12 50-12-1 50-16 50-18 50-19 50-23 50-26 50-27 50-31E 50-32 50-34 50-38N 50-38W Overload 460V, 3PH Overload 575V, 3PH Capacitor 115 Capacitor 230 Pump Top Cover O-Ring (Kit Only) Power Cable w/ Gland - 115V, 1 PH Power Cable w/ Gland - 230V, 1 PH, No Plug Power Cable w/ Gland - 3 PH O-Ring (Kit Only) O-Ring (Kit Only) Ground Wire w/Ring Term.
RX SERIES PARTS LIST Pos. No.
24 24 26 26-1 27 27 27 27-1 27-2 31E 32 34 35 38 38F 38F 50-01-2 50-07 50-08 50-11 50-11-1 50-12 50-12-1 50-16 50-18 50-19 50-23 50-27 50-31E 50-32 50-34 50-38N 50-38W Overload 575V, 3PH Capacitor 115 Capacitor 230 Bolt - Suction Cover O-Ring (Kit Only) Power Cable w/ Gland-115V, 1PH Power Cable w/ Gland- 230V, 1PH, No Plug Power Cable w/ Gland- 3PH O-Ring (Kit Only) O-Ring (Kit Only) Ground Wire w/Ring Term. Power Cord Line Clip Handle Rod Bolts Disch.
SINGLE PHASE WIRING DIAGRAM 115V & 230V W/O GOVERNOR SWITCH MODELS R100, R250, R400 R400D, R400P 24
SINGLE PHASE WIRING DIAGRAM 115V & 230V W/GOVERNOR SWITCH MODELS R750, RX750SS, R1500, RX1500SS, R1520 & R1530 25
THREE PHASE WIRING DIAGRAM MODELS R08, RX08SS, R15, RX15SS (230V) 26
THREE PHASE WIRING DIAGRAM MODELS R08, RX08SS, R15, RX15SS(460V) 27
BJM PUMPS, LLC 123 Spencer Plain Road Old Saybrook, CT 06475, U.S.A.
START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a later date (if needed). BJM Pumps, LLC 123 Spencer Plain Road Old Saybrook, CT.
START-UP REPORT FORM presence? Are guide rails exactly vertical? Yes No Is base elbow installed level? Yes No Liquid level controls: Model Is control installed away from Yes No turbulence? Operation Check Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex). Tip fourth float (and stop float), high level alarm on (omit on simplex).
START-UP REPORT FORM Voltage supply at panel line connection, pump on L1-L2 L2-L3 Amperage load connection, pump on L3-L1 L1 L3 L2 Is pump secured properly? Was pump checked for leaks? Do check valves operate properly? FINAL CHECK Yes No Yes No Yes No Flow: Does station appear to operate at Yes proper rate? Noise level: Acceptable Unacceptable Comments: Describe and equipment difficulties during start-up Installed by: Company: Person: Date: Maintained by: Company: Person: Date and time of
NOTES:
BJM Pumps, LLC 123 Spencer Plain Road • PO Box 1138 • Old Saybrook, CT 06475, USA • Phone: (860) 399-5937 • Fax: (860) 399-7784 Email: sales@bjmpumps.com • Web Site: www.bjmpumps.com BJM Pumps is a registered trademark of BJM Pumps, LLC. Copyright © 2006-2013 BJM Pumps, LLC All rights reserved.