User manual

98
Return String:
237
Pins 9, 8, 7, 4, 3, and 1 are outputs and the rest are
inputs. (See “Table 9” to convert the binary
representation). Refer to section3.13 Digital I/O
” for
more details.
Format:
<NR1>
Measure Subsystem
MEASure:CURRent?
Description:
Queries the measured current value
Query:
MEAS:CURR?
MEASure:CURRent?
Return String:
1.234
The measured current is 1.234 A.
Format:
<NRf>
MEASure:CURR2?
Note:
For dual channel models only.
Description:
Queries the measured current value of channel 2
Query:
MEAS:CURR2?
Return String:
1.234
The measured current is 1.234 A.
Format:
<NRf>
MEASure:VOLTage?
Description:
Queries the measured voltage value.
Query:
MEAS:VOLT?
MEASure:VOLT?
Return String:
1.234
The measured current is 1.234 V.
Format:
<NRf>
MEASure:VOLT2?
Note:
For dual channel models only.
Description:
Queries the measured voltage value of channel 2
Query:
MEAS:VOLT2?
Return String:
1.234