User manual

132
Example 2:
Return string: 00008C
Byte 2: 0
Byte 1: 0
Byte 0: 8C
8C = 10001100 (bits 7 bit 0)
Representation:
- Channel 1 OVP status is ON
- Channel 1 output is ON
- Channel 2 output is ON
- LCD backlight is ALWAYS ON
- Output mode is MULTI
- No protection flag status (instrument is operating normally)
TRACK
Note:
This command is for dual channel models only.
Description:
Configures/Queries the tracking mode state.
Syntax:
TRACK<SP><state>
TRACK?
<state> - ON or 1 to turn ON
- OFF or 0 to turn OFF
Example:
TRACK ON
Turns ON (enables) tracking mode.
Query:
TRACK?
Return String:
ON
Format:
<state>
VERsion?
Description:
Queries the firmware version
Syntax:
VERsion?
Example:
VERsion?
Return String:
1.10
Format:
<NRf>