User manual

136
PROG 1
PROG:RUN ON
Select program 1
Use RUN ON command to execute
Example 2:
To create an output sequence like above, send the following list of
commands in order:
PROG 2
Choose program number
PROG:CLE
Clear program 2 data
PROG:REP 0
No repeat after running this program
PROG:TOTA 8
Set program 2 to have 8 steps in total
PROG:STEP 1
Settings for step 1
PROG:STEP:CURR 2
Set output current to 2 amperes
PROG:STEP:VOLT 20
Set output voltage to 20 volts
PROG:STEP:ONT 0.5
Set output ON time to 0.5 sec
PROG:STEP 2
Choose step 2
PROG:STEP:CURR 2
PROG:STEP:VOLT 15
PROG:STEP:ONT 0.5
PROG:STEP 3
Settings for step 3
PROG:STEP:CURR 2
PROG:STEP:VOLT 20
PROG:STEP:ONT 0.5
PROG:STEP 4
Choose step 4
PROG:STEP:CURR 2
PROG:STEP:VOLT 10