User manual

149
Example:
GOC 3.000
Sets all the power supplies’ OCP value to 3.000 A.
GOCP/GOCP2
Description:
Configures/Queries the over current protection state of
all the power supplies connected in the chain. See
OCP/OCP2 command for similar syntax. GOCP2 is for
dual channel models only.
Example:
GOCP ON
Sets all the power supplies’ OCP state to ON.
Error List
Using any of the commands for multi unit programming for
configuration, a response string is returned. If the command was
sent successfully to the power supply(s) (except for Synchronous
Control Commands), the return string will be “OK”. If otherwise, an
error message will occur. See the tablebelow for the list of errors
and their descriptions.
Table 10- Error List for Multi Unit Programming
Return String Description
Time out Wait response time has timed out
Range error Input value is out of range
Multi master
More than one master is in the
chain.