User manual

44
Current Limit Set
1. Press , then to enter OUTPUT SETTING. Press
to select CURR LIMIT SETTING.
2. CURR LIMIT MAX should be selected. Use the keypad to
enter the maximum current set limit and press to save
changes. The maximum current that can be set depends on
the power supply’s maximum output current.
3. CURR LIMIT MIN is now selected. Again, use the keypad to
enter the minimum current set limitand press to save
changes.
4. Press once to return to previous menu items, or press
three times to exit the menu when finished.
Dual Channel Models
For models with dual channels, the display will look different, with
CH1 and CH2 indicators on the left side of the display to indicate
their respective CURR LIMIT MAX/MIN parameters.
CH1 VOLT LIMIT MAX = _20.400 V
CH1 VOLT LIMIT MIN = 0 V
CH2 VOLT LIMIT MAX = _20.400 V
CH2 VOLT LIMIT MIN = _ 0.000 V
Menu
2
2
Enter
Enter
Esc