Modem 34336
Table 5-2. Hayes Mode Result Codes.
DIGIT
CODE WORD CODE MEANING
0 OK Command line executed without errors.
1 CONNECT Carrier detected at 0-300, 1200, or
2400 bps (basic code set).
2 RING
Ringing signal detected (in answer mode).
(When the Modem detects a ring, it
sends a RING result code unless it is in
the process of accepting a command.
However, the Modem answers the call
only if it is set for automatic answer or is
given an A command.)
3 NO CARRIER Carrier lost or never detected.
4 ERROR Error in command line, invalid command,
command line exceeds 40 characters, or
invalid character format.
5 CONNECT 1200 Carrier detected at 1200 bps.
6 NO DIALTONE No dial tone detected.
7 BUSY Busy signal detected.
8 NO ANSWER No period of silence detected. This code
appears only if @ (wait for silence before
dialing) is included in the dial string.
10 CONNECT 2400 Carrier detected at 2400 bps.
11 CONNECT 1275 Modem is on-line in V.23 mode
(1200/75 bps).
13 CONNECT 12.0 Carrier detected at 12,000 bps.
14 CONNECT 14.4 Carrier detected at 14,400 bps.