User`s guide

V.25 bis Autodialer
11-10 Modem 3600
INVMSInvalid command - message syntax error.
Example:RLL;
LSLList linked numbers.
In all LSL examples, if no number is stored at the specified address no
response is sent. The separator field for BISYNC is an
<etb><sp><sp><stx>LSL<sp>
The last LSL string ends with <etx> per V.25 bis. For synchronous bit
oriented operation, each LSL string is treated as an individual message
per V.25 bis. All linked numbers are sent to the DTE as
LSLa;l{sep}a;l
where a = stored address and l = link address.
Request List of Version RLV
The request list of version information command is an RLV with no
parameters.
Responses:
INVCUInvalid command - command unknown.
Example:TLV
INVMSInvalid command - message syntax error.
Example: RLV;
LSVList version
The version information is sent to the DTE as
LSV<sp>Sbbbbbbb00sccppddr /
comment field
where bbbbbbb is the board number, s is the series number, cc is the
controller code revision, pp is the data pump code revision, dd is the
board dash number, and r is the printed circuit board revision followed
by a comment field.
MODEM OPTIONS COMMAND PRO xxx;yy;0;0...
The program options command is PRO followed by the starting register
address (1 to 3 decimal digits), option count (1 or 2 decimal digits) and
the data for each option (1 to 3 decimal digits per option). The
Options section on pa ge11-14 lists all available options with
definitions, possible settings, and default values.