Test Sheet

BEST TEST SERVICE SHENZHEN CO.,LTD Page 7 Of 17
UTILIZATION FACTORS TABLE
NAME:
SPEC.:
MFR.: Blackjack Lighting
TYPE:FLR-48L-BL or WH or SN
DIM.:
SUR.:1.2*0.06
WEIGHT:
SERIAL No.:
Shielding Angle:
Test:U:120.00V I:0.3486A P:41.633W PF:0.9947 Freq:60.00Hz Lamp Flux:2080.32x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 58 47 40 58 47 40 56 46 40 33
0.80 69 57 50 68 57 50 66 56 50 43
1.00 77 67 60 76 66 59 74 67 59 52
1.25 85 75 68 83 74 67 81 72 67 59
1.50 90 80 74 88 79 73 85 78 72 65
2.00 97 88 82 95 87 82 91 85 80 73
2.50 100 93 87 98 92 86 94 89 85 77
3.00 104 97 92 101 96 91 97 93 89 81
4.00 107 102 98 105 100 96 101 97 94 85
5.00 110 105 101 107 103 100 103 100 97 88
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEG
C Interval: 10.0DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.366
Temperature:25.6DEG Humidity:67.1%
Test Distance:26.000m [K=1.0000]Operators:David
Test Date:12 June 2018 Remarks: