Test Sheet

Blackjack Lighting Model: FLR-48L-BL or WH or SN
Report No.BTR66.181.17.0032.24 Page 2 of 5 IESNA LM-79 Test Report
description:
Test date ............................................ :
Jun 11, 2018 to Jun 12, 2018
Sample Quantity ................................ :
1 unit
SKU .................................................... :
N/A
Rating(s) (V; Hz) ................................ :
120V 60HZ
Nominal Power ................................... :
42W
Nominal Power Factor ....................... :
N/A
Nominal Lumen Output ...................... :
2000LM
Nominal CCT ..................................... :
3000K
Nominal CRI(Ra) ............................... :
90
Number of hours operated prior to
measurement
0H
Total operating time of the product for
measurements including stabilization
3.5H
Ambient temperature
24.7
Orientation (burning position) of SSL
product during test
Lighting Surface Down or Base Up
Stabilization time
1.5 H
Photometric method Sphere-spectroradiometer+Goniophotometer
Calibration standard lamp used
DC 24V 100W Omni-Directional Halogen Calibrated by NIM
China(Sphere)
DC 120V 500W Omni-Directional Halogen Calibrated by NIM
China(Goniophotometer)
Correction factors applied Self absorbing applied
Photometric measurement conditions See test method description below
Equipments used
EVERFINE HASS-2000 Sphere System
CHROMA 61602 AC Source
YOKOGAWA WT 310 Power Meter
FLUKE 52II
EVERFINE GOR-5000 Goniophotometer
CALIFORNIA INSTRUMENT 1501I AC Source
YOKOGAWA WT 210 Power Meter
FLUKE 233 Temperature Meter
Bandwidth of spectroradiometer 2nm
Statement of uncertainties 1.12%
Deviation from standard operating
procedures,
None