User manual

The following table shows which ambient temperature is correct for each climate classification:
If installation next to a source of heat is unavoidable, the following minimum clearances must be main-
tained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If the refrigeration appliance is installed next to another refrigerator or freezer a clearance of 5 cm at
the sides is required, in order to prevent the formation of condensation on the outside of the appliance.
Instructions for totally built-in appliances
Door reversibility
The appliance’s door has been locked in position for transport by
means of pins on both sides. According to the door opening direction,
remove relevant pins at the top and at the bottom.
Installation
Dimensions of the recess
Height of housing mm 880
Depth of housing mm 550
Width of housing mm 560
It is necessary that the niche is provided with a conduct of ventila-
tion having the following dimensions:
Depth 50 mm
Width 540 mm
For safety reasons, minimum ventilation must be as shown in Fig.
Attention!
Keep ventilation openings clear of obstruction.
21
Climate classification for an ambient temperature of
SN +10 to +32 °C
N +16 to +32 °C
ST +18 to +38 °C
T +18 to +43 °C
B
A
540
50
560
550
880