Specifications

9
5. Connect neutral and earth conductors to neutral stud
and earth stud respectively.
6. For all connections ensure that conductors are secure
and appropriately terminated.
7. Tighten the cable gland to secure against tension on
the cable.
8. Check that the polarity of each connection is correct
to the mains connection terminals markings on the
appliance.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an
all-pole disconnection switch.
9. Correctly locate the appliance into its final operating
position and using a spirit level, adjust the legs so
that the appliance is level and at the correct height.
10. Connect the power supply to the appliance.
11. Check that the electrical supply is within the input
rating specification, refer to the 'Specifications'
section).
Commissioning
1. Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
'Operation' section of this manual.
Light the Target Top Pilot Burner.
Light the Target Top Main Burner.
Check the Target Top Low Fire Burner operation.
Check the Target Top High Fire Burner operation.
Check the Oven Heating.
Check the Oven Thermostat operation.
Check the Oven Fan operation (GEC models only).
Check the current draw and loading for the equipment. Refer specification section for correct
electrical requirements.
Check that all the connections are correct and that all cover panels have been re-fitted.
Ensure that this instruction manual is left with the appliance.
Ensure that all the relevant details and contacts have been added to the front of this manual.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2. This manual must be kept by the owner for future reference, and a record of the
Date of
Purchase,
Date of Installation
and
Serial Number of the Appliance
recorded and kept with
this manual.
(These details can be found on the Rating Plate attached to the front right
hand corner of the bottom sill. Refer to the ‘Gas Connection’ section).
NOTE:
If for some reason it is not possible to get the appliance to operate correctly, turn off the
electrical power and gas supply and contact the supplier of this appliance.
Make sure that the electrical and gas supply are turned off before any service or
maintenance work is carried out on the appliance.
Installation
Add bridging
wires between
L1, L2 and L3.
Neutral supply
connection to N
Phase supply
connection to L1
P
N
C
AUTION
:
Changing the supply from 3 phase to single phase will increase the electrical
current loading on the supply cable. Ensure that the supply cable used is of a
sufficient size for the current loading, refer to the 'Electrical Supply
Requirements' table overleaf.
Fig 3