Specifications

4
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130mm from the
right hand side, 32mm from the rear and 655mm from the floor and is reached from beneath the
appliance. An optional underside connection is available. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
Electrical Connection
Electrical supply connection point is located at the rear of the appliance, approximately 69mm from
the right hand side and 484mm from the rear and 150mm from the floor.
When connecting a this electric appliance to the mains supply, ensure that the following is carried
out:-
An isolating switch is fitted within 2m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
Specifications
WARNING:
T
HIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
MODEL
1-Phase Connection
1P+N+E
230-240V
3-Phase Connection
3P+N+E
400-415V
GE570
6.5kW,
26.6 Amps @ 235V
6.5kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE576
6.8kW,
27.9 Amps @ 235V
6.8kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps