Product Manual

12
POWER SUPPLY MODE
Connect the BC15/BC25 to the mains supply and select Power Supply mode by
depressing and holding the Charge Rate selection button for 10+seconds, or until all
three LEDs in the bottom row are illuminated with the 3rd LED illuminating constant
orange.
Connect positive and negative leads of the BC15/BC25 corresponding to the load
terminals. Ensure clamps do not get short with each other in order not to degrade
the metal and to avoid spark.
Power Supply mode is limited to 10Amp output for BC15 and 20Amp for BC25.
While in Power Supply Mode, drawing current beyond the specified current limit
may cause the output to have high ripple of more than 1V, a condition that could be
detrimental to some loads. It is therefore necessary to operate within or lower than
the specified current limits.
Note: While in Power Supply mode, do not operate beyond the specified current limit
or the voltage may become unstable.
CAUTION
Failure to observe these instructions properly may result
in property damage, which may be serious depending on
the circumstances.