5. AUX+
Connection point for external DC input positive.
6. BATT+
Connection point for battery positive and negative terminal.
Attach fuse to Batt+ wiring
7. BATT-
8. NOT USED
9. RESET (MASTER RESET BUTTON)
Press the Master Reset Button if any part of the system is
unresponsive or not operating correctly during or after installation
10. CAN BUS COMMUNICATION CONNECTOR
To connect to and power BMPRO accessories (BC300 + CommLink
External Shunt or OdysseyLink) or monitors (RVView or Trek).
11. REMOTE SWITCH TERMINAL BLOCK (RSW)
Terminal block for connecting an optional remote switch. This switch
is used to disconnect the loads from all power
Terminals are labelled according to their designated load output
Table 3: Designated terminal-load outputs
TERMINAL OUTPUTS LOAD RATING
1 Tablet / Spare 15A
2 Spare 15A
3-9 Spare 10A
10 Light 1 10A
11 Light 2 10A
12 Light 3 10A
13 Pump 1 10A
14 Pump 2 10A
11