Problem Solving
WEAC628
Problem Solving
ALL MAINTENANCE CAN ONLY BE PERFORMED BY A QUALIFIED SERVICE PERSON.
PROBLEM PROBABLE CAUSE REMEDY
a Power Failure a Wait for power to be turned
on.
b Tripped Circuit Breaker b Reset circuit breaker
c Blown Fuse c Replace
Unit fails to start
d Electrical Fault d Climate Technologies Service
a Pump Seized a Refer to Maintenance page.
See Pump section.
b Electrical fault with pump b Climate Technologies Service
Filter Pads not
wetting.
c Low voltage in your area c Remove water restrictor at
bleed tee. See page 14.
a Float Valve Leaking a Check adjustment or replace
float valve if necessary
Water leaking from
overflow
b Drain from CELdek
®
Pads b Normal Operation – adjust
float level
a Loose Delivery Tube a Check and tighten
b Break in tubing b Replace as necessary
c Pump appears to deliver
excessive water to pads
c Check the condition of the
filter pad. Wash if pad shows
heavy build up of minerals
Water Droplets in
air stream
d Bleed nozzle is blocked d Clean bleed nozzle
a Not enough air flow a Increase fan speed
b Inadequate Exhaust b Provide more open area to
exhaust stale air by opening
windows and doors in
adjacent rooms.
Excessive humidity
a Dirty Filters a Clean
Inadequate
Cooling
b Dry Filters b Check control set on COOL
mode. Check water delivery
system. Adjust if necessary.
a Unit located near odour source a Remove source
Unpleasant Odour
b Algae in water tank b Clean tank and refill with fresh
water.
High Mineral Content Bleed off should be checked
to see if bleed nozzle is
blocked, clear if necessary
and clean CELdek
Rapid formation of
white deposits on
pads
®
pad.
Increase the bleed rate – see
page 14. More regular
maintenance may be required.