Owner`s manual

BONAIRE DURANGO WINDOW COOLER
Installation
Installation
INSTALLATION REQUIREMENTS
Tools
- Drill (Power or Cordless)
- Adjustable Wrench.
- Phillips Head Screw Driver
- Drill bits for drilling pilot holes into window frame. 1/8" (3.2mm) drill or appropriate for
size of screw used.
- ¾” Philips Head Screws for affixing Window Infill Panel
Materials Required (Not supplied)
- Silicone for sealing Window Infill Panel
- Copper or plastic high pressure water pipe for mains water supply.
- 840mm (33”) of suitable spacer material (if required)
I
NSTALLATION
Note that it is not necessary to remove the Rear filter panel from the unit
for installation.
Do not connect the power to the cooler until the installation is complete.
External Fixing Of the Unit
Ensure that the location chosen to mount the cooler is strong enough to support the
operating weight of the unit. The unit’s nominal operating weight is 42 kg.
Ensure that the window opening is large enough for the neck of the cooler (nominally
550mm high by 650mm wide).
Ensure there is a minimum 100mm (4”) clearance above the external cabinet for
maintenance purposes.
Position the cooler through the window (two or more people will be required for this) so
that the unit is hard up against the outside wall of the house.
Note that if the cooler does
not fit hard up against the
outside wall (e.g. a
protruding timber or brick
window sill), utilise a spacer
block of wood (not
provided) which must be
attached to the wall (the
unit is then fixed to this
wood).
Page 7