LP Gas Conversion Kit Installation Manual

English 9
Test Flame
Verify that flame characteristics are as shown in Figure 4
Checking Flame Characteristics”. If flame characteristics
are not consistent with those in the graphic above, adjust
flame as described below.
Adjust Bake Flame (if necessary)
Adjust the air shutter to alter the flame characteristics. The
oven burner air shutter is located to the left of the oven
regulator. Reach it through the access hole in the interior
back panel of the warming drawer
1. Loosen screw and turn shutter. Close the shutter if the
flame is lifting or blowing or not carrying over; open the
shutter if it is too yellow. (See Figure 6). Tighten screw.
Call Service if:
1. Any of the burners do not light.
2. The broil burner or bake burner does not stay lit.
3. The bake burner does not cycle.
Service
Before Calling
Service
See Use and Care Manual for troubleshooting information.
Refer to the Statement of Limited Product Warranty in the
Use and Care Manual.
To reach a service representative, see the contact
information at the front of the manual. Please be prepared
with the information printed on your product rating label
when calling.
Rating Label
The rating label shows the model and serial number.
Refer to the rating label on the appliance when requesting
service. The rating label is located on the back side of the
drawer front. Open the drawer to see it.
Figure 6: Bake Air Shutter Adjustment
Shutter
More Open:
Less Yellow Flame
Less Open:
Less Blue Flame
More Carryover
Less Lifting or Blowing
Rating Label