Specifications

Page 20 from 63
6720649497 SM HP270-1 2012/09 en
Position
(Scheme Nr)
Model
+5ºC / +35ºC
Model
-10ºC / +35ºC
Component Characteristics
A15 X X Expansion valve TLK 2.0 R134a / MOP + 15ºC
A2 X X Evaporator 14 x 3 tubes
A20 / B16 X Solenoid Valve 230 V / 50 Hz
A1 / B11 X X Fan
230 (196 - 253) Vac
50 (47,5 - 52,7) Hz
85 W
A3 / B7 X X Compressor
230 (198 - 264) Vac
50 (47,5 - 52,5) Hz
520-565 W / 475-490W
(Mitsubishi / Highly)
B6 X X Compressor Capacitor
17 μF / 15 μF
(Mitsubishi / Highly)
B8 X X Compressor Protection
Bimetallic thermal switch
(open at 160ºC, close at 70ºC)
B4 X X
Supply Cable to control
unit
230 V (+10% / -15%), 50 Hz
B5 X X High Pressure Switch
Temp. = 60ºC
Opening pressure = 27 bar*
Closing pressure = 20 bar*
B9 X X Low Pressure Switch
Temp. = 5ºC
Opening pressure = 0,7 bar*
Closing pressure = 2,4 bar*
A10 / B12 X X Electric resistance 230 V / 50 Hz (R=26,5)
A10 / B13 X X Safety Thermostat T
sec
= 90ºC
B14 X X Control Unit 230 V (+10% / -15%), 50 Hz
* Relative pressures
Table 2 – Schemes A and B - components identification