Specifications

Page 60 from 63
6720649497 SM HP270-1 2012/09 en
Soldering equipment
To soldering components in
repairs in the refrigeration circuit.
Thermal paste (protect heat
transmission to surrenders)
To avoid damages in the
components near of the soldering
points
Nitrogen Kit
For circulation inside of refrigerant
circuit during brazing process
1) Nitrogen cylinder
2) Nitrogen pressure
regulator
3) Nitrogen transfer hose
with 1/4” female flare SAE
connection
Manometers group (R134a)
For the measurements of
refrigeration operation pressures
and temperatures, for the
purpose of refrigerant transfer
and for system evacuation, a
service gauge manifold is used.
1) Manifold body
2) Manifold body
3) Sight glass for refrigerant
flow
4) Low pressure valve
5) Vacuum pump valve
6) High pressure valve
7) Valve connection for
charging cylinder or
recovery unit
8) Hose connection
1/4”male flare SAE
9) Vacuum hose connection
1/4” and 3/8”
Flexible hoses
To use always with the same gas
type and to be connected from
the manometers kit to the vacuum
pump or recovery station.
1) Refrigerant standard
hose with 2 x 1/4” SAE
female flare connection
2) Adjustable and
replaceable core-depressor
(valve opener) ‘schematic’