Specifications

o(contin.e¢ PLAN THE DUCTWORK
Note: The high level of airflow of this appliance may affect the gas
flame on some types of gas cooktops. This is NORMAL and wil!
cause no harm, but can be corrected by lowering the speed of the
blower.
,I OISCNARGEt
I 120160MAxl6OUl0"ROUND
Install downdraft with Model DHG565AUC Exterior Blower.
TAKE MEASUREMENTS
Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
Model DHD805AUC will fit in most 30" wide cabinets and the
Model DHD905AUC will fit in most 36" wide cabinets. How°
ever, it is recommended that oversized cabinets be used for
easier installation.
Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
10" ROUND
DISCHARGE
1. This downdraft blower system is most efficient when used with
10" round ductwork.
2. For best performance: Choose the duct!rig option which allows
the shortest length of ductwork and a minimum number of
elbows. Check location of floor joists, wall studs, electrical
wiring or plumbing for possible interference.
8" ROUND EQUALS6 FT, OF
ELBOW STRAIGHTDUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The illustrations,
above, shows equivalent feet of elbows. The number of feet of
straight duct plus the equivalent feet of elbows to be used
should equal 40 feet or less.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of the
cooktop and the inside of cabinet back.
PLAN THE W RING
1,
2_
The downdraft and exterior blower system normally draws 6
AMPS and requires a 120 VAC, 60 Hz circuit.
The unit has a 2 ft. long power cord with a 3opronged plug. Plan
to provide a grounded outlet in a location which will allow the
unit's power cord to reach. (Note: If the Model DHD805AUC is
being installed in a 30" wide cabinet orthe Model DHD905AUC
is being installed in a 36" wide cabinet, the outlet cannot be
located on the back wal! of cabinet.) Outlet may also be wall-
mounted, with access hole in cabinet.